The scientific water replenishment device technology is an energy-saving measure widely adopted by the Ministry of Electric Power. It is a calculation and analysis method for thermodynamic systems using the enthalpy drop method, which has developed in recent years. Add a scientific water replenishment device in the condenser turbine condenser
Online inquiry
上一產品 : Secondary filter screen
  • Content details

The scientific water replenishment device technology is an energy-saving measure widely adopted by the Ministry of Electric Power. It is a calculation and analysis method for thermodynamic systems using the enthalpy drop method, which has developed in recent years. Add a scientific water replenishment device in the condenser turbine condenser, scientifically spray chemical water replenishment, rapidly cool the discharged steam, thereby improving the vacuum and heat recovery economy of the unit. At the same time, increase the water temperature entering the deaerator, reduce the oxygen content, and improve the deaeration rate of the deaerator. After adopting this scientific water replenishment device, coal consumption can be reduced by 1-3 grams per kilowatt hour. The investment can be recovered within six months.


Diagram 1 of the scientific water replenishment device for condensers


Working principle and function of scientific water replenishment device:


We have determined that the water replenishment is at the throat of the condenser. Based on the size of the condenser throat, we determine the position of the pipeline layout of the 銀行卡water replenishment energy-saving device銀行卡 inside the condenser. The replenishment water is atomized from the throat through the 銀行卡water replenishment energy-saving device銀行卡 and can form an 銀行卡atomization belt銀行卡, which flows through the shaft seal cooler, air extractor, and low-pressure heater before reaching the deaerator. The energy generated by this process is:


1. Supplementing water absorbs a certain amount of heat, resulting in a significant increase in the feedwater temperature. This increases the low-pressure system extraction volume, reduces the high-pressure extraction volume, improves the thermal power conversion rate, and allows this portion of steam to work inside the unit.


2. Supplementing water in the condenser absorbs heat from the exhaust steam, reduces a certain proportion of balance loss, strengthens heat exchange, lowers the exhaust steam temperature, and improves the vacuum of the unit.


3. The condenser performs vacuum deoxygenation on the make-up steam, improving the deoxygenation capacity of the entire regenerative system.


4. And it is conducive to the load connection of the unit.


The condenser uses this scientific water replenishment device - discharge potential:


The scientific water replenishment device is an energy-saving measure widely adopted by the Ministry of Electric Power. It is a calculation and analysis method for thermodynamic systems using the enthalpy drop method, which has developed in recent years. In the condenser, a set of chemical and scientific water replenishment energy-saving system is added, which sprays chemical and scientific water into the condenser to quickly cool the discharged steam, thereby improving the vacuum and heat recovery economy of the unit. At the same time, the water temperature entering the deaerator is increased, the oxygen content is reduced, and the deaeration rate of the deaerator is improved. After adopting the chemical science water replenishment energy-saving system, coal consumption can be reduced by 1-3 grams per kilowatt hour. The investment can be recovered within six months.


Scientific water replenishment technology transformation plan and determination of relevant parameters:


1. Scientific water replenishment device - selection of application plan. Based on the on-site system, select the source of water replenishment, whether it is from the unit or from the main pipe, and then determine the position and spatial size of water replenishment into the condenser throat.


2. Determination of water replenishment amount. The amount of water replenished into the condenser is limited by the following main factors: the flow capacity of the condensate pump, main extraction unit, shaft seal cooler, and low-pressure heater. Secondly, it is limited by its deoxygenation capacity. For the determined unit and condenser (steam turbine condenser) chemical science water replenishment energy-saving system device, its deoxygenation capacity is determined. If the amount of replenishment water is too large, it will not be able to make the oxygen content of the replenishment water below the required value, causing the oxygen content of the condensate to reach the standard, thereby corroding the condensate pipeline. Furthermore, during operation, the amount of supplementary water should also match the load carried by the unit.


Precautions for the use, operation, and installation of scientific water replenishment devices:


1. Based on the size of the condenser throat, determine the position of the pipeline layout of the 銀行卡chemical science water replenishment device銀行卡 inside the condenser.


If the unit undergoes minor repairs, the installation period can be half a day. If the cylinder is not suspended for installation, the installation period can be - days.


3. A flow orifice plate can be installed on the pipeline from the chemical science water replenishment device to the condenser, and the flow indicator can be installed on the operating layer to provide a basis for operators to adjust the water replenishment amount.


4. In order to enable operators to timely and conveniently understand the water level of the condenser and adjust the make-up water flow rate, valve control flow and the entire system anti siphon pipeline can be used, or an 銀行卡electric connection water level gauge銀行卡 can be installed on the operating panel.


5. Operators can adjust the make-up water flow rate based on the economic parameters and load of the unit.


6. The support of the 銀行卡scientific water replenishment energy-saving device銀行卡 inside the condenser should be firmly fixed to prevent loosening.


Instructions for ordering scientific water replenishment devices:


1. The use of chemical science water replenishment equipment requires a water replenishment amount of at least one ton per hour. (T/H)


2. Diagram of the position and spatial dimensions of the condenser throat. (Copy)


3. Is the system supplying water from the unit or from the main pipe.


4. Provide excess condensate pump capacity


Technical parameters of scientific water replenishment device:



型號補水量(t/h)-率相對提高(%)供電煤耗(g/kw.h)年節(jié)煤(t/a)
BS-10100.2251-3337.5
BS-20200.450675.0
BS-30300.7201080.0
BS-40400.9001350.0
BS-50501.1251687.5
BS-60601.3502025.0
BS-70701.5752362.5
BS-80801.8002700.5
BS-90902.0253037.5
BS-1001002.2253413.0
BS-1101102.4753712.5


產品動態(tài)

Scientific water replenishment device生產廠家Copyright ? 2012-2023 Lianyungang Lingdong Electromechanical Equipment Co., Ltd all rights reserved

Tel

0518-85370171

日本一卡二卡新区乱码绿野仙踪| 乱亲女H秽乱长久久久| 性色AV网站| 日产无码精品一区二区三区| 精品精品国产高清a毛片| 亚洲中文久久精品无码99| 色哟哟哟| 奇米网888| 亚洲午夜无码久久久久软件 | 国产欧美日韩另类精彩视频| 国产成人免费无码AV在线播放 | 日本bbwbbw| 禁漫网站进入网站| 沙洋县| 久久久99久久久国产自输拍| 亚洲VA韩国VA欧美VA| 综合欧美日韩国产成人| 欧美三级 欧美一级| 色综合色综合蘑菇在线| 无码国产精品一区二区免费式直播 | 99久久人妻精品免费一区| 最新国产av无码专区亚洲| 亚洲欧美日韩一区二区三区| 综合乱码av蜜桃avavav| 日韩啪啪视频| 精品亚洲成在人线AV无码| 国产精品原创av片国产日韩| 精品久久久无码中文字幕边打电话| 五月天丁香网| 午夜黄视频| 色悠久久久久综合欧美99| 狠狠色噜噜狠狠狠8888米奇| 久久婷婷国产综合亚洲91| 99久久精品无免国产免费| 欧美性猛交富婆| 人人妻人人爽人人澡欧美一区| 久久精品午夜福利| 欧美人与动牲交a欧美精品| 日本六十路熟女| 精品一区二区无码av| 亚洲人AV在线无码影院观看|